Summer is the time of year when most swimming pool equipment hot tubs and spas are inspected and maintained to ensure that life saving measures such as ground fault circuit interrupter gfci protection and all grounding and bonding systems are functioning properly.
Swimming pool electrical code.
All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection.
10 horizontal from the pool wall.
All electrical equipment used with storable pools are required to be gfci protected.
2008 national electrical code 2010 residental code of new york state permanently installed swimming pools.
Electric pool cover mechanisms.
2017 national electrical code sps 316 swimming pool wiring nec article 680 680 5 gfci s may be either circuit breakers or receptacle type.
A swimming pool or spa installation must follow a couple of rules when it comes to overhead electrical lines.
Top 10 major code changes to look out for in the nec 2017.
Metal parts separated from the pool by a permanent barrier that prevents contact by a person are not required to be bonded 680 26 b 7 ex 1.
1 pool pump receptacle outlet and wiring methods a.
Electrical outlet receptacles near swimming pools.
Differences in potential can exist between any metallic equipment electrical or not.
Swimming pool rules and regulations found in the uniform fire prevention and building code uniform code please note that this web page is not intended to be the document required by executive law section 376 6.
680 9 overhead wire clearance is min.
Examples of 2020 national electrical code changes.
Cord length for a pump motor is 3 except for storable pools.
Thus you bond it all unless it fits one of the exceptions.
This web page includes a brief summary of some but not all of the uniform code s requirements relating to swimming pools.
For added protection of all new pool installations the 2017 nec national electrical code article 680 has been amended.
Thanks for your electrical question sue.
Utility power lines that run over a pool or spa must be at least 22 5 feet above the water level or base of a diving platform.
All electrical installations in walls or decks close to swimming pools must follow these requirements.
Electrical wiring requirements for swimming pools permanently installed swimming pools are those that are constructed in the ground or partially in the ground and all others capable of holding water with a depth greater than 42 inches 1067 mm 1 pool pump receptacle outlet and wiring method a.
National electrical code definition are those pools that are constructed or partially in the ground all others pools capable of holding water with a depth greater than 42 inches.
If the pool is an above ground and is considered storable then the following codes apply.